Make-up air units replace the air a building exhausts with heated, and where needed cooled, outside air. Titan Air offers direct-fired units as well as indirect-fired, electric, chilled water, hot water, steam and packaged DX arrangements.

Direct-fired make-up air

  • TA Series: replaces all exhausted building air with heated outside air. ETL listed to Z83.4 / CSA 3.7, from 1,200 to 120,000 CFM single speed, with a maximum 120°F temperature rise on natural gas and LP.
  • Demand Air: variable air volume, from 4,000 to 120,000 CFM, with a variable frequency drive that adjusts supply air to changing exhaust loads.
  • TAM: compact, lightweight units for competitively priced or short-lead-time projects.
  • Recirculating (AR) systems: ETL listed to Z83.18.

Standard features

  • Galvanized casing and base, factory tested, pre-piped and pre-wired, with built-in filter section and lifting provisions.
  • Forward-curve industrial blowers and a premium-efficiency motor with starter and overload protection.
  • Direct-fired burner with electronic flame supervision and standard gas-train safety switches.
  • Door-interlocked disconnect, discharge air temperature control, a summer-off-winter selector and contacts for exhaust fan interlock.

Options

  • Chilled water, DX or direct evaporative cooling modules, and energy recovery sections
  • Intake and discharge dampers, hoods, diffusers and filter options
  • VFDs, DDC or PLC systems, clogged filter switches and smoke detectors
  • Custom configurations and dimensions, double-wall doors and insulation options

Discharge arrangements

Titan units are offered in a range of fan and discharge arrangements. Knowing which one an existing unit has makes a replacement easier.

Titan Air discharge arrangements: HRH, HRD, HRV, HLH, HLD, HLV, VRH, VLH and VRV/VLV
Titan Air discharge arrangements (others available).

Sectioned units may need field assembly, wiring and piping.

What we need to help you size it

Titan Air has sizing calculations it uses for this application. Send us what you have and we will work with Titan on the selection. It is fine if you do not have everything, and plans or a sketch help.

  • Supply airflow, and the exhaust airflow it must replace
  • Outside design temperature and required discharge temperature
  • Fuel and electrical service, and whether the unit is indoors or outdoors
  • Cooling or energy recovery requirements
  • Controls, building automation and exhaust interlock requirements

Titan Air literature

Request a quote for industrial make-up airReplace or upgrade an existing unit

Prefer to call? 651.698.0089 or info@jjmorgan.com.

Other Titan Air applications

Air turnover · Paint booth and finishing make-up air · Food processing cooling · Building pressurization · Custom air handling

Capacities, options and examples come from Titan Air’s published brochures and project pages (titan-air.com) and depend on the model and configuration.

John J. Morgan Company, Titan Air Manufacturer’s Representatives
1413 Thompson Avenue, Suite 1, South St. Paul, MN 55075 · 651.698.0089 · info@jjmorgan.com